Garage light Wiring - Screwfix Community Forum
Mar 21, 2014 · I have a basic understanding of wiring and i recently wired up my whole garage with 6x two gang sockets also utilising one of them as a spur into the room on the other side of the wall. My next task is to wire up two tube lights on the roof controled by 2 switches (one at one end of the garage, one at the other), with the mains power coming ...
Wiring for LAP LED battens in garage - Screwfix Community Forum
Mar 15, 2021 · Minor change of plan, looked into their IP20 lights (An entire pound cheaper!) appear to have provision for the wiring of actual 3 core wire into and out of the light, so that should be better all round. I'm going to go for 2 high up at the front, 2 at the rear, and one in the middle - that should give a good light spread.
Wiring 2 outside lights to 1 switch - Screwfix Community Forum
Jan 24, 2019 · I currently have 2 lights on the outside (1 either side) of my garage door with a separate PIR sensor fitted between them above the garage. I need to replace this arrangement with 2 lights (built in PIRs) both wired to a single internal switch. From what I can see - a cable is running from 1 light to the sensor
Garage Wiring.....Electrician Advice required - Screwfix Community …
Jan 18, 2016 · Lights are connected with 1.5mm^2 T&E Solid cable Power supply to the garage comes from a 13A fused spur in the utility and connects to a 13A fused switch in the garage using 1.5mm^2 armored cable. The fused switch is used to operate the lights in the garage. The length of armored cable from the house spur to garage is circa 8 meters and all ...
Wiring to the summerhouse from the garage - Screwfix …
Nov 3, 2019 · Garage has fused switch and a twin socket. A small freezer and a tumble dryer runs from the socket. The summer house is approx 3.5 square meters in size. It is approx 10 meters away from the garage and I plan to have the following-- 2 twin sockets-- under floor heating using a 3 sq meter mat -- 10m LED strip light -- 4 LED down lights
Adding electricity to a garage from a main consumer unit in the …
Nov 12, 2018 · Im looking at adding electricity to my garage. The armoured cable is already in place but its just connected to a 16amp Circuit breaker in the house CU and then just a plug socket in the the garage. I understand thats not right so I was planning 1. Placing a 2 gang CU with 40A 30mA RCD in the garage with a 20 or 25amp MCB for the 1 double socket 2.
LED batten fixing to garage - Screwfix Community Forum
Sep 29, 2020 · The light you list is great - but depending on the size of your garage, and the use, it may be a better option to fit 2 or 3 smaller LED battens to get better light spread. And at risk of all sorts of flak - just wire it/them up to the existing light fixture.
Sockets in Garage.... - Screwfix Community Forum
Aug 9, 2019 · I have a detached single garage, with the lekky coming from the house (from the main board on a 16a breaker). The cable goes from the house under the concrete path to garage. Garage has two double sockets and a strip light (no breaker in garage). Looks like a 2.5mm cable for sockets and 1.5mm cable for light. 1.
Garage LED batten lights - Screwfix Community Forum
Oct 1, 2022 · They would not be in series they would be in parallel, re using a JB or wiring through, I have done both and combinations of them both it just depends on the cable and light layouts. For example cable coming up from switch to middle of a squarish shaped garage and the fittings coming of evenly from the middle point so it would made sense to ...
PIR garage lighting, that can be switched to always on when needed.
Dec 9, 2024 · I currently have a 1 gang intermediate switch as I enter the garage from the inside of the house and I think a 1 gang 2 way switch on my way out the garage side door. There's nothing near the up and over door that I leave from. Each garages has a single pendant light, that comes on together via the intermediate or 2 way switch.